INSTRUCTIONS FOR CHARGING MODE

 

 

In charging mode:

  • Shore power (utility or generator) is connected and supplying 15AAC (1800W: 15AAC x 120VAC) - 1.
  • No power is required by the appliances (fridge, TV, charger).
  • Batteries are being charged up to 100 Amps (with the 2000W) or 125 AMPs (with the 3000W) DC per hour - 2.

 