You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close
GP-RVC-R - USER INTERFACE
print icon

STARTUP SPLASH SCREENS

The following splash screens are displayed when the controller/remote display are first powered on.

[MENU 1]: RVC-DISPLAY Establishing connection with the controller (this interface only exists for a very short time)
[MENU 2]: RVC-DISPLAY startup, displays Go Power!



1. Main Screen

Displays PV Voltage, Current, BAT1 and BAT2’s Voltage and Current, Solar Controller Internal Temperature, Solar Controller Charge State / Fault, and Bluetooth Connection Status. Section 5 provides additional detail of the Solar Controller Charge State / Fault display.



2. Status Screens

The status screens show detailed status information that is not on the main screen. The following steps can be used to get to the status screens shown as [MENU4] to [MENU8] and navigate through them. A detailed explanation of each status parameter is included in a table in section 4 below.

Short press [ENTER] button go to status interface
Short press [BACK] button to quit status interface and go to main interface
Short press [DOWN] button: the menu’s sequence is [MENU4]->[MENU5]->...->[MENU8]->[MENU4]
Short press [UP] button: the menu’s sequence is [MENU8]->[MENU7]->...->[MENU4]->[MENU8]

Note: 10A controllers do not have BAT2 parameters
Note: Each time the [DOWN] [UP] buttons are pressed, it will enter next interface



3. Setting Screens

The settings screens are used to view and edit settings and also to issue commands to the controller. The following steps can be used to get to the settings screens shown as [MENU9] to [MENU16] and navigate through them. A detailed explanation of each setting parameter is included in a table in section 4 below.
Long press [ENTER] button go to system setting interface Short press [BACK] button quit setting interface and go to main interface
Short Press [DOWN] button to move down by one setting (the curser wraps back to top when you reach the bottom)
Short press [UP] button to move up by one setting (the curser wraps back to bottom when you reach the top)
Press [ENTER] on a setting to edit and use [DOWN] and [UP] to change value. [ENTER] locks setting in and [BACK] cancels setting.

Note: 10A controllers do not have BAT2 parameters
Note: Each time the [DOWN] [UP] buttons are pressed, it will enter next interface
Note: The small black triangle before the parameter item indicates the currently selected item
Note: When the user sets the parameter, the value of the parameter item will flash, and the user can change the setting

The following steps can be used to get to the settings screens shown as [MENU9] to [MENU16] and navigate through them.

Feedback
0 out of 0 found this helpful

scroll to top icon