You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close

Showing articles from ic 3000 tag

IC Series Inverter/Charger: FINAL INSPECTION

# Steps on Final Inspection 1. Verify all cables/conduit runs are secured with zip ties or other non- conductive cable clamps to prevent damage from vibration. 2. Ensure all cables that pass-through walls, bulkheads, or any other openings are protected against abrasion by using strain reliefs and/or grommets. 3. Ch…

IC Series Inverter/Charger: AC WIRING 2 - Single Phase, 30A> Service, Single IN /Single OUT [Sub Panel]

![][1] [1]: https://hf-files-oregon.s3.amazonaws.com/hdpgopower_kb_attachments/2020/05-08/ff0c2316-e73b-4a01-b6fb-8329f87c8eac/wire%202.jpg

IC Series Inverter/Charger: BATTERY TEMPERATURE SENSOR (BTS) OPERATION

# BATTERY TEMPERATURE SENSOR (BTS) OPERATION The IC Series Inverter/Charger is delivered with a battery temperature sensor. By installing this sensor, the charge voltages are automatically adapted for deviating temperature. With a BTS installed, if the temperature around the BTS is below 20°C, the absorb and float ch…

IC Series Inverter/Charger: POWER SHARING MODE 2

# POWER SHARING MODE 2 **In generator mode**: * The power required by the appliances (fridge, TV, outlets) is 3600W (30AAC x 120VAC) - 1. * Shore power (utility or generator) is connected and supplying 2400W (20AAC x 120VAC) - 2. * The inverter automatically switches on and supplies the remaining 1200W (10AAC…

IC Series Inverter/Charger: DISABLING THE NEUTRAL TO CHASSIS GROUND CONNECTION

# HOW TO DISABLE THE NEUTRAL TO CHASSIS GROUND CONNECTION The IC Series Inverter/Charger has the automatic neutral to ground switching feature enabled as a factory default setting. In some installations this feature must be physically disabled by disconnecting the neutral to chassis ground connection. Please consult …

IC Series Inverter/Charger: AC CONDUCTOR WIRING

![][1]Make sure the IC Series is fully disconnected from the battery bank and no AC power is connected to the Inverter/Charger before commencing any AC wiring connections. Tighten terminal blocks on both sides periodically to correct torque specs. AC INPUTS WIRING (50A Dual IN, Dual Out Configuration) * Remove th…

IC Series Inverter/Charger: DC GROUNDING

DC GROUNDING INSTRUCTORS To protect against electrical shock hazards the IC Series metal chassis must be connected to the DC grounding system. The DC grounding system is sometimes referred to as the earth ground or another designated ground. For example, on an RV, the metal frame of the RV is designated as the negati…

IC Series Inverter/Charger: AC POWER PASS-THROUGH MODE

# AC POWER PASS-THROUGH MODE In AC power pass-through mode: * Shore power (utility or generator) is connected. * The power required by the appliances (fridge, TV, charger) is 3600W (30AAC x 120VAC) - 1. * Shore power is powering all the appliances (3600W) - 2. * Batteries are not being charged. ![][1] […

IC Series Inverter/Charger: BATTERY TEMPERATURE SENSOR INSTALLATION

# Installation Steps The Battery Temperature Sensor (BTS) extends the life of the battery by preventing overcharging in warm temperatures and undercharging in cold temperatures. The BTS provides the Inverter/Charger with precise battery temperature information to automatically adjust the absorb and float charge volta…

scroll to top icon