IC Series Inverter/Charger: GROUNDING ON BOATS

# Grounding Information If you are installing the IC Series Inverter/Charger on a boat there are some specific guidelines/standards to follow. The Inverter/Charger must be installed adhering to the standards of the ABYC (American Boat and Yacht Council). Some guidelines are outlined below but these notes do not repla…

IC Series Inverter/Charger: MOUNTING THE DRIP SHIELD

# MOUNTING THE DRIP SHIELD The IC Series Inverter/Charger is Marine UL listed. In order to properly mount the Inverter/Charger in a marine application, you must use a drip shield. Please follow the installation instructions below. **WALL MOUNT** ![][1] 1. Use the screws to mount the drip shield on the wall. ![][2…

IC Series Inverter/Charger: GFCI (GROUND FAULT CIRCUIT INTERRUPTION) OUTLETS

# GFCI (GROUND FAULT CIRCUIT INTERRUPTION) OUTLETS SPECIFICATION Compliance with UL standards requires that Go Power! test and recommend specific GFCIs for use on the AC output of the IC Series. GFCIs shall be installed in the AC output wiring system to proceed all branch circuits. A GFCI is a device that de-energiz…

IC Series Inverter/Charger: CHARGING MODE

# INSTRUCTIONS FOR CHARGING MODE **In charging mode**: * Shore power (utility or generator) is connected and supplying 15AAC (1800W: 15AAC x 120VAC) - 1. * No power is required by the appliances (fridge, TV, charger). * Batteries are being charged up to 100 Amps (with the 2000W) or 125 AMPs (with the 3000W) DC…

IC Series Inverter/Charger: TESTING THE INSTALLATION

# How to test the Installation 1. Apply battery power to the inverter by engaging the fuse, switching the breaker on or switching the battery disconnect switch to the ON position. The Inverter/Charger will remain off. 2. Disconnect all AC loads from the breaker panel by switching the main on/off breaker or all indiv…

IC Series Inverter/Charger: KIT PARTS AND PARTS CHECKLIST

Please unpack and make sure all parts shown in the list below are included in the IC Series Inverter/Charger kit. If any parts are missing please contact Go Power!’s customer service team at [[email protected]][1]. ![][2] [1]: mailto:[email protected] [2]: https://hf-files-oregon.s3.a…

IC Series Inverter/Charger: AC TERMINAL BLOCK CONNECTIONS

# AC TERMINAL BLOCK CONNECTIONS The IC Series has a six-pole AC terminal block and two AC ground terminals to connect the Inverter/Charger’s AC input and output wiring. The terminal block and ground terminals can be accessed by removing the three Phillips screws holding the AC cover plate. Each connection on the AC…

IC Series Inverter/Charger: DC OVERCURRENT PROTECTION AND DC DISCONNECT

# DC OVERCURRENT PROTECTION AND DC DISCONNECT Batteries are capable of providing very large currents in case of a short circuit. If this occurs with no DC overcurrent protection, it will result in overheating and melting of the cables and possibly serious injury and/or fire. DC overcurrent protection is not included…