You are using an unsupported browser. Please update your browser to the latest version on or before July 31, 2020.
close

Showing articles from ic2000 tag

IC Series Inverter/Charger: GROUNDING ON BOATS

If you are installing the IC Series Inverter/Charger on a boat there are some specific guidelines/standards to follow. The Inverter/Charger must be installed adhering to the standards of the ABYC (American Boat and Yacht Council). Some guidelines are outlined below but these notes do not replace the full guidelines de…

IC Series Inverter/Charger: DC GROUNDING

To protect against electrical shock hazards the IC Series metal chassis must be connected to the DC grounding system. The DC grounding system is sometimes referred to as the earth ground or another designated ground. For example, on an RV, the metal frame of the RV is designated as the negative DC ground/RV ground. On…

IC Series Inverter/Charger: GFCI (GROUND FAULT CIRCUIT INTERRUPTION) OUTLETS

Compliance with UL standards requires that Go Power! test and recommend specific GFCIs for use on the AC output of the IC Series. GFCIs shall be installed in the AC output wiring system to proceed all branch circuits. A GFCI is a device that de-energizes a circuit when a current exceeds a specified value that is less…

IC Series Inverter/Charger: UNIT DIMENSIONS

![][1] ![][2] [1]: https://hf-files-oregon.s3.amazonaws.com/hdpgopower_kb_attachments/2020/02-18/86038789-2e14-402c-b0d4-7b0c0ec48509/IC%20dims%20top.jpg [2]: https://hf-files-oregon.s3.amazonaws.com/hdpgopower_kb_attachments/2020/02-18/476a8c79-cf72-45c6-8c69-a82351e6f70e/IC%20dims%20side.jpg

IC Series Inverter/Charger: AC WIRING

The AC cables link the Inverter/Charger to the main panel and the sub panel. These cables handle the incoming alternating current (AC) utility or generator power, which can be passed through the Inverter/Charger to directly power the main appliances (pass-through mode) and/or used to charge the batteries (charging mod…

IC Series Inverter Charger: DC CABLE CONNECTIONS

When installing the battery cable ring lug onto the Inverter/Charger DC terminal and the battery post, do not put anything between the ring lug and the metal surface. Incorrectly installed hardware causes a high resistance connection which could lead to poor Inverter/Charger performance and may melt the cable and term…

IC Series Inverter/Charger: PREPARING THE DC CABLES

Go Power! supplies 2 ring lugs with the IC Series, which can be used for the Inverter/Charger end of the DC Cables. Source the correct ring terminals for the batteries you are using. * Cut the negative and positive cables to the required length. * Strip off enough insulation so you can install the ring lugs provi…

IC Series Inverter/Charger: AC WIRING 2 - Single Phase, 30A> Service, Single IN /Single OUT [Sub Panel]

![][1] [1]: https://hf-files-oregon.s3.amazonaws.com/hdpgopower_kb_attachments/2020/05-08/ff0c2316-e73b-4a01-b6fb-8329f87c8eac/wire%202.jpg

IC Series Inverter/Charger: DC OVERCURRENT PROTECTION AND DC DISCONNECT

Batteries are capable of providing very large currents in case of a short circuit. If this occurs with no DC overcurrent protection, it will result in overheating and melting of the cables and possibly serious injury and/or fire. DC overcurrent protection is not included with the IC Series. It must be installed betwe…

IC Series Inverter/Charger: UNIT ACCESSORIES

The IC Series Inverter/Charger has two accessories available: * IC Series remote (not included). * Battery temperature sensor (included). **IC Series Remote** This remote control device can be used for monitoring the performance of the unit. It is also used to program certain settings on the Inverter, Charger,…